PRODUCTS

PRODUCTS AND
     SOLUTIONS

Permanent magnet variable frequency low-voltage SLVC series

Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving Feature: IE4 Permanent Magnet Motor / WEG Brand High Efficiency IE4 Motor Optional oil cooled engine Advantages : Engine efficiency 97% Benefit: 5% energy saving

Send Mail    Consulting    Facebook

Product advantages

  • Feature
    Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings
    01
  • Benefits
    Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving
    02
  • Advantages
    Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings
    03
Model Maximum Working Pressure Productivity (fad) Power
Electric motor
Appearance
Transmission
Diameter
Pipes
Exports
Size (mm) Wes
bar psig m³/min cfm kw hp inch L In H kg
SLVC-30A 2.0 29 2.9~11.3 102.4~398.9 30 40 Direct
drive
DN80 2000 1400 1895 2000
2.5 36 2.5~10.1 88.3~356.5
SLVC-37A 2.0 29 3.4~14.0 120.0~494.2 37 50 Direct
drive
DN80 2000 1400 1895 2100
2.5 36 3.1~12.2 109.4~430.7
3.0 44 3.5~11.5 123.6~406.0
4.0 58 2.5~10.1 88.3~356.5
SLVC-45A 2.0 29 4.0~16.0 141.2~564.8 45 60 Direct
drive
DN100 2300
(2500)
1680
(1700)
1890
(2050)
2600
3.0 44 3.5~13.8 123.6~487.1 DN80 2000 1400 1895 2200
4.0 58 3.0~11.2 105.9~395.4
SLVC-55A 2.0 29 5.2~21.0 183.6~741.3 55 75 Direct
drive
DN100 2300
(2500)
1680
(1700)
1890
(2050)
2700
2.5 36 4.8~19.3 169.4~681.3
3.0 44 4.4~17.6 155.3~621.3
3.5 51 4.4~17.0 155.3~600.1
4.0 58 4.0~16.0 141.2~564.8
SLVC-75A 2.0 29 7.1~28.0 250.6~988.4 75 100 Direct
drive
DN125 2430
(2580)
1740
(1760)
2000
(2020)
3600
2.5 36 6.3~25.3 222.4~893.1
3.0 44 5.8~23.1 204.7~815.4
3.5 51 5.8~22.5 204.7~794.3
4.0 58 5.2~21.0 183.6~741.3 2300
(2500)
1680
(1700)
1890
(2050)
3000
SLVC-90A 2.0 29 8.6~36.5 303.6~1288.5 90 120 Direct
drive
DN125 3000
(3140)
1840
(1910)
1920
(2090)
4500
2.5 36 8.6~34.8 303.6~1228.4 4200
3.0 44 7.9~32.0 278.9~1129.6
3.5 51 7.5~29.0 264.8~1023.7
4.0 58 7.0~25.6 247.1~903.7 2430
(2580)
1740
(1760)
2000
(2020)
3600
SLVC-110A 2.0 29 11.6~47.2 409.5~1666.2 110 150 Direct
drive
DN150 3440
(3540)
2050
(2200)
2290
(2340)
5900
2.5 36 9.8~38.8 345.9~1369.6 3000
(3140)
1840
(1910)
1920
(2090)
5000
3.0 44 9.2~36.8 324.8~1299.0 DN125 4800
3.5 51 8.6~34.8 303.6~1228.4
4.0 58 7.9~31.0 278.9~1094.3
SLVC-132A 2.0 29 13.2~51.8 466.0~1828.5 132 175 Direct
drive
DN150 3440
(3540)
2050
(2200)
2290
(2340)
6000
2.5 36 11.8~50.3 416.5~1775.6
3.0 44 11.8~47.2 416.5~1666.2
3.5 51 9.8~40.2 345.9~1419.1 DN125 3000
(3140)
1840
(1910)
1920
(2090)
5000
4.0 58 8.6~38.0 303.6~1341.4
SLVC-150A 2.0 29 14.0~56.5 494.2~1994.5 150 200 Direct
drive
DN150 3440
(3540)
2050
(2200)
2290
(2340)
6300
2.5 36 12.5~55.0 441.3~1941.5
3.0 44 12.5~50.0 441.3~1765.0
3.5 51 11.8~47.5 416.5~1676.8
4.0 58 9.8~40.2 345.9~1419.1 DN125 3000
(3140)
1840
(1910)
1920
(2090)
5100
Model Maximum Working Pressure Productivity (fad) Power
Electric motor
Appearance
Transmission
Diameter
Pipes
Exports
Size (mm) Wes
bar psig m³/min cfm kw hp inch L In H kg
SLVC-160A 2.0 29 16.6~62.8 586.0~2216.8 160 215 Straight
Drive
DN150 3440
(3540)
2050
(2200)
2290
(2340)
6400
2.5 36 15.6~60.6 550.7~2139.2
3.0 44 14.0~56.6 494.2~1998.0
3.5 51 12.5~50.3 441.3~1775.6
4.0 58 11.8~47.0 416.5~1659.1
SLVC-185A 2.0 29 17.8~71.3 628.3~2516.9 185 250 Straight
Drive
DN200 4500
(4500)
2250
(2250)
2440
(2440)
8000
2.5 36 16.6~67.6 586.0~2386.3 4340
(4340)
2250
(2250)
2440
(2440)
3.0 44 15.6~62.9 550.7~2220.4 DN150 3440
(3540)
2050
(2200)
2290
(2340)
6600
3.5 51 14.0~56.6 494.2~1998.0
4.0 58 12.5~50.0 441.3~1765.0
SLVC-200A 2.0 29 20.5~81.8 723.7~2887.5 200 270 Straight
Drive
DN200 4500
(4500)
2250
(2250)
2440
(2440)
8600
2.5 36 17.8~71.2 628.3~2513.4 8200
3.0 44 16.6~67.6 586.0~2386.3 4340
(4340)
2250
(2250)
2440
(2440)
3.5 51 15.6~62.9 550.7~2220.4 DN150 3900
(3900)
2400
(2400)
2440
(2440)
7000
4.0 58 14.0~56.6 494.2~1998.0
SLVC-220A 2.0 29 22.2~88.7 783.7~3131.1 220 300 Straight
Drive
DN250 5000
(5000)
2400
(2400)
2600
(2600)
9400
2.5 36 20.4~81.6 720.1~2880.5 DN200 4500
(4500)
2250
(2250)
2440
(2440)
8800
3.0 44 18.3~73.1 646.0~2580.4 4400
(4400)
2250
(2250)
2440
(2440)
3.5 51 16.6~67.5 586.0~2382.8 4340
(4340)
2250
(2250)
2440
(2440)
8200
4.0 58 15.6~62.6 550.7~2209.8 DN150 3900
(3900)
2400
(2400)
2440
(2440)
SLVC-250A 2.0 29 25.6~102.5 903.7~3618.3 250 340 Straight
Drive
DN250 5000
(5000)
2400
(2400)
2600
(2600)
9600
2.5 36 22.8~91.3 804.8~3222.9
3.0 44 21.0~83.6 741.3~2951.1 DN200 4400
(4400)
2250
(2250)
2440
(2440)
9000
3.5 51 19.3~77.1 681.3~2721.6
4.0 58 16.6~69.0 586.0~2435.7 DN150 3900
(3900)
2400
(2400)
2440
(2440)
8600
SLVC-280A 2.5 36 25.6~102.5 903.7~3618.3 280 375 Straight
Drive
DN250 5000
(5000)
2400
(2400)
2600
(2600)
9800
3.0 44 23.5~93.9 829.6~3314.7
3.5 51 21.4~85.5 755.4~3018.2 DN200 4400
(4400)
2250
(2250)
2440
(2440)
9200
4.0 58 19.8~79.1 698.9~2792.2
SLVC-300A 3.0 44 25.6~102.2 903.7~3607.7 300 400 Straight
Drive
DN250 5000
(5000)
2400
(2400)
2600
(2600)
10000
3.5 51 23.5~93.8 829.6~3311.1
4.0 58 21.0~87.4 741.3~3085.2 DN200 4400
(4400)
2250
(2250)
2440
(2440)
9400
SLVC-315A 3.5 51 25.5~102.1 900.2~3604.1 315 420 Straight
Drive
DN250 5000
(5000)
2400
(2400)
2600
(2600)
10500
4.0 58 23.4~93.6 826.0~3304.1
SLVC-330A 4.0 58 25.5~101.9 900.2~3597.1 330 440 Straight
Drive
DN250 5000
(5000)
2400
(2400)
2600
(2600)
10500

In accordance with Appendix E of ISO 1217, the complete set of equipment is freely supplied at an ambient temperature of 20°C and an absolute inlet pressure of 1 bar.
Sound pressure from 64 DB (a) according to Din en ISO 2151:2009
Technical specifications can be changed