PRODUCTS

PRODUCTS AND
SOLUTIONS

Water lubrication single-stage compression frequency conversion series

Feature: Screw block with single stage air compression
Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving Feature: IE4 Permanent Magnet Motor / WEG Brand High Efficiency IE4 Motor Optional oil cooled engine Advantages : Engine efficiency 97% Benefit: 5% energy saving

    Quick Quote
    ×



      Consulting Facebook
    1
    2
    3

    Product advantages

    • Feature
      Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings
      01
    • Benefits
      Feature: Screw block with single stage air compression Advantages: Low compression level Low temperature rise Low air leakage Integrated shaft (direct drive) Benefit: 5% energy saving
      02
    • Advantages
      Feature: Dual VFD System Benefits : Constant pressure output to eliminate pressure fluctuations and load shedding Constant outlet temperature at 80-85℃ Low inrush current to protect components Benefit: 15% energy savings
      03
    ModelMaximum
    Working Pressure
    DURATIONKW Motor
    Power
    dB noiseCooling water inlet and
    outlet
    diameter
    Cooling
    Water
    Inlet Water
    Temperature-Desaturation

    32%
    coolant
    L
    Dimensiones
    L*W*H
    mm
    Weight
    kg
    Inch air
    outlet
    barpsigm³/mincfm
    SW-06A/W81160.7827.55.5583/4″1.510800X800X12004303/4″
    101450.6521.18
    SW-08A/W81161.1540.67.5583/4″210800X800X12004703/4″
    101451.0236
    12.51810.8128.6
    SW-11A/W81161.5554.711601″2.5261150X755X13405803/4″
    101451.3246.6
    12.51811.0135.7
    SW-15A/W81162.3081.215631″3.5261150X755X13406503/4″
    101452.1274.8
    12.51811.6056.5
    SW-18A/W81163.10109.418.5651″4301400X900X14507051″
    101452.6292.5
    12.51812.1074.1
    SW-22A/W81163.42120.722651″5301400X900X14507451″
    101453.15111.2
    12.51812.6292.5
    SW-30A/W81165.05178.330671 1/2″7401550X1150X1550(A)11001 1/4″
    101454.20148.3
    12.51813.18112.31500X1150X1300(W)
    SW-37A/W81166.10215.337671 1/2″9401550X1150X1550(A)11501 1/4″
    101455.25185.3
    12.51814.85171.21500X1150X1300(W)
    SW-45A/W81167.60268.345681 1/2″10901980X1300X1760(A)13902″
    101456.15217.1
    12.51815.65199.41800X1300X1680(W)
    SW-55A/W81169.60338.955701 1/2″121201980X1300X1760(A)14702″
    101458.55301.8
    12.51817.45263.01800X1300X1680(W)
    SW-75A/W811613.00458.975731 1/2″181202100X1600X2000(A)22502″
    1014511.42403.1
    12.51819.85347.72200X1500X1800(W)1630
    SW-90A/W811616.25573.690731 1/2″201802400X1600X2000(A26502 1/2″
    1014514.55513.6
    12.518112.30434.22200X1550X1800(W)2350
    SW-110A/W811619.50688.4110782″241803000X1700X2250(A)31502 1/2″
    1014516.80593.0
    12.518115.15534.82200X1550X1800(W)2460
    SW-132A/W811622.52795.0132782″302403000X1700X2250(A)35002 1/2″
    1014520.30716.6
    12.518118.25644.22200X1550X1800(W)2500
    SW-160W811628.11992.3160803″352402700X1800X20503700DN80
    1014524.50864.9
    12.518122.15781.9
    SW-185W811633.651187.8185803″383002700X1800X20503750DN80
    1014528.51006.1
    12.518124.5864.9
    SW-200W811636.631293.0200804″423002700X1800X20503900DN100
    1014532.751156.1
    12.518127.50970.8
    SW-220W811639.501394.4220804″473602700X1800X20504200DN100
    1014535.801263.7
    12.518129.501041.4
    SW-250W811640.501429.7250804″583602700X1800X20504600DN100
    1014536.301281.4
    12.518132.501147.3

    Note: air and water cooling.

    Variable frequency technical parameters
    ModelMaximum
    Working Pressure
    DURATIONKW Motor Power
    dB noiseCooling water inlet and
    outlet
    diameter
    Cooling
    Water
    InletWater
    Temperature-Desaturation

    32%
    coolant
    L
    Dimensiones
    L*W*H
    mm
    Weight
    kg
    Inch air
    outlet
    barpsigm³/mincfm
    SWVC-06A/W81450.3-0.7810.6-27.55.5583/4″1.510800X800X12004603/4″
    101450.2-0.657.1-22.9
    SWVC-08A/W81160.35-1.1512.4-40.67.5583/4″210800X800X12005103/4″
    101450.3-1.0210.6-36.0
    12.51810.24-0.818.5-28.6
    SWVC-11A/W81160.54-1.5519.1-54.711601″2.5261150X755X13406203/4″
    101450.45-1.3215.9-46.6
    12.51810.35-1.0112.4-35.7
    SWVC-15A/W81160.75-2.3026.5-81.215631*3.5261150X755X13406703/4″
    101450.65-2.1222.9-74.8
    12.51810.6-1.6021.2-56.5
    SWVC-18A/W81160.9-3.1031.8-109.418.5651″4301400X900X14507301″
    101450.9-2.6231.8-92.5
    12.51810.6-2.1021.2-74.1
    SWVC-22A/W81161.1-3.4238.8-120.722651″5301400X900X14507801″
    101450.97-3.1534.2-111.2
    12.51810.85-2.6230.0-92.5
    SWVC-30A/W81161.55-5.0554.7-178.330671 1/2″7401550X1150X-1550(A)11501 1/4″
    101451.26-4.2044.5-148.3
    12.51811.10-3.1838.8-112.31500X1150X-1300(W)
    SWVC-37A/W81161.91-6.1067.4-215.337671 1/2″9401550X1150X-1550(A)12001 1/4″
    101451.60-5.2556.5-185.3
    12.51811.42-4.8550.1-171.21500X1150X-1300(W)
    SWVC-45A/W81162.50-7.6088.3-268.345681 1/2″10901980X1300X-1760(A)14902″
    101451.91-6.1567.4-217.1
    12.51811.70-5.6560.0-199.41800X1300X-1680(W)
    ModelMaximum
    Working Pressure
    DURATIONKW Motor
    Power
    dB noiseCooling water
    inlet and
    outlet
    diameter

    Cooling
    Water
    Inlet Water Temperature-Desaturation

    32%
    coolant
    L
    Dimensiones
    L*W*H
    mm
    WeiWeight
    kg
    Inch air
    outlet
    barpsigm³/mincfm
    SWVC-55A/W81163.0-9.60105.9-338.955701 1/2″121201980X1300X-1760(A)15702″
    101452.56-8.5590.4-301.8
    12.51812.30-7.4581.2-263.01800X1300X-1680(W)
    SWVC-75A/W81163.95-13.00139.4-458.975731 1/2″181202100X1600X-2000(A)22502″
    101453.40-11.42120.0-403.1
    12.51813.0-9.85105.9-347.72200X1500X-1800(W)1750
    SWVC-90A/W81165.0-16.25176.5-573.690731 1/2″201802400X1600X-2000(A)31502 1/2″
    101454.30-14.55151.8-513.6
    12.51813.72-12.30131.3-434.22200X1550X-1800(W)2450
    SWVC-110A/W81166.0-19.50211.8-688.4110782″241803000X1700X-2250(A)31502 1/2″
    101455.07-16.80179.0-593.0
    12.51814.65-15.15164.1-534.82200X1550X-1800(W)2580
    SWVC-132A/W81166.75-22.52238.3-795.0132782″302403000X1700X-2250(A)350021/2″
    101456.0-20.30211.8-716.6
    12.51815.07-18.25179.0-644.22200X1550X-1800(W)2700
    SWVC-160A/W81168.5-28.11300.1-992.3160803″352402700X1800X20503900DN80
    101457.6-24.50268.3-864.9
    12.51816.7-22.15236.5-781.9
    SWVC-185W814510-33.65353.0-1187.8185803″383002700X1800X20504050DN80
    101458.72-28.5307.8-1006.1
    12.51817.75-24.5273.6-864.9
    SWVC-200W811611.2-36.63395.4-1293.0200804″423002700X1800X20504200DN100
    101459.68-32.75341.7-1156.1
    12.51819.2-27.50324.8-970.8
    SWVC-220W811612.2-39.50430.7-1394.4220804″473602700X1800X20504400DN100
    1014511.2-35.80395.4-1263.7
    12.51819.0-29.50317.7-1041.4
    SWVC-250W811613.5-40.50476.6-1429.7250804″583602700X1800X20504800DN100
    1014512.3-36.30434.2-1281.4
    12.518110.2-32.50360.1-1147.3
    Application Area

    Food industry, such as transportation, filling, packaging, and other processes.
    In the medical field, gas is used in medicines, vaccines, etc., especially in hospitals.
    In the textile industry, compressed air can affect the quality and hygiene of fabrics.
    Process requirements such as the high-precision instrument industry and board manufacturing.
    Laboratory applications, analytical tests, chemical tests, etc.